air retention for at least 2 seconds at a temperature of less than 850C, the combustion
In order to achieve the proper effect.
? must be a two-chamber incinerators, primary and secondary
Fuel stoves
? The waste products to reduce the initial volume
Possible to minimize (approximately 5% sterile ash
Form).
Purpose: Top Loader incinerator of general, medical and dry waste to comply with the requirements of the Air Quality
Act, 2004 (Act No 39 of 2004)
1 Design standard Retort type, multiple
2 Description of chimney Top mounted, self supporting, unlined
3 Stack height from base At least 11 meter (depends on height above sea level)
4 Incineration performance Capacity 750 kg/hour
5 Temperature Primary Minimum 850 degree Celsius
6 Temperature Secondary Minimum 1000 degree Celsius
7 Dimensions (minimum)(cm)
Length
Width
Height
210
180
210
8 Loading door opening (m) 200
9 Description of grate/hearth Full
10 Primary chamber volume (minimum) 1.05 cubic meters
11 Tools included Poker, hoe, rake
12 Materials of construction (minimum)
Case
Bracing
Hearth
Ashing door
Loading door
? Chamber Volume: 0.1m3
? Load method: Front
? Fuel options: Diesel or Natural gas
? Typical fuel: Liquid propane gas: 6 liters per hour
? Consumption: Natural gas: 6 liters per hour