medical waste heat value

18   Electrical supply required 3-phase 19   Auxiliary fuel      Diesel or paraffin 20   Primary burner 21 Secondary (after) burner 22 Type of burners   Automatic pressure jet 23   Output Primary   Approx 600 000 kJ/hour 24   Output Secondary      Approx 750 000kJ/hour 25 Emission control Heated …

INCINERATOR DIESEL DRIVEN

BURNER, DIESEL DRIVEN waste kind: MEDICAL CARE WASTE Waste calorific well worth: 4000KCAL/KG Dampness Content: 10-25%. Small Capacity: 50Kg/Hour set tons. 2nd Chamber: 2 Secs @ 850degrees C. The major burning chamber have to ensure very little leave temperature degree is not …

medical incinerators in china

Would plant operations be operational on a basis of 24 hours per day, 7 days a week, all year long except for regular and preventive maintenance periods?   How many hours per year could your process be operational?   What would be …

incinerators from china

An operating test should be conducted to ensure that all of the control components have been properly installed and that all parts of the incinerator, including controls and safety devices, are in satisfactory operating condition. The requirements for prepurge and time between …

pet cremation incinerators

The successful bidder shall deliver the incinerator skid in a container. The container will be emptied by CEB and returned to the successful bidder / or to its shipping agent. A containerized solution is also acceptable. Electrically operated 220 volt ( 60 …

incineration combustion chamber

Supervision of installation of the new incinerator set shall be provided by the successful Bidder while labour and heavy duty equipment shall be provided by CEB.     ?     The successful Bidder shall submit to CEB, prior to shipment of the incinerator …

smart ash incinerator price

Flue Gas Cleaning   System   ? Wet Scrubber   ? Electrostatic precipitation in combination ( Optional: Rate to be   quoted separately)     7 Chimney Height 10m (minimum)       ?     Total duration of the supervision of installation, testing …

laboratory incinerator china manufacturer

Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol range 0‐1200 C, thermocouple, air supply capacity 10m3/ minute, power consumption 1.2kWH/ hour, power 3 phase with netral, cooling water sprinkler capacity 5L/ minute, completed with refractory (insulation, castable, …

animal incinerators china

Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency …

animal crematorium equipment

I also research their product details and find it don’t require fuel and also not require fan blower but that incinerator can only burn waste with 30%-40% humid. I see if your products can burn waste with 30%-40% humid without fan blower …